External control: weak signal or lost link
Blocking: it retries by itself
The meaning depends on the boiler: on a WTC-GW C series boiler, the remote control signal an external controller sends to input N1 has been too low for about 15 minutes; on a Thermo Condens WTC-A, the WCM-KA cascade manager no longer sends a correct setpoint, and on a WTC-OB, communication with the cascade manager or the WCM-Sol module is disturbed. This is a warning: the boiler does not lock out and the message clears by itself once the cause is removed.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show W80?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code W80
The meaning depends on the boiler: find yours below.
Control signal input N1 too low
The WCM-KA cascade manager no longer sends a valid set point
Communication problem with the cascade manager or WCM-Sol.
What our technician checks
- The signal on input N1 (WTC-GW C series)
- The power supply and eBus link of the cascade manager (WTC-A, WTC-OB)
- The WCM-KA cascade manager
- The address set in parameter 12