Calibration too high, condensate blocked or transfer failed
Breakdown: the boiler is stopped
On a WTC-GW or WTC-GB B series boiler and on a Thermo Condens WTC-A, the combustion (SCOT) calibration gives too high a value, beyond the factory limits; on a WTC-GW C series boiler the condensate drain is blocked, and on a WTC-OB oil boiler the data transfer to the electronics has failed. The boiler locks out and stops heating until our technician has found the cause.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F64?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F64
The meaning depends on the boiler: find yours below.
Calibration: SCOT base value too high
Condensate drain blocked
The new calibration value exceeds the factory limits
The data transfer was not carried out correctly.
What our technician checks
- The ionisation electrode and its cable
- The burner, to be cleaned, and the cleanliness of the combustion air
- The flue tightness (no flue gas recirculation)
- The condensate trap (WTC-GW C series)
- The data transfer from the coding key to the WCM-OB-CPU board (WTC-OB)