Flame lost at ignition or no solar flow
Breakdown: the boiler is stopped
On a WTC-GW or WTC-GB B series boiler, the meaning depends on the device showing the code: on the boiler's combustion manager, the flame went out during ignition (safety time); on the solar module, no water is flowing through the solar collector circuit. It is a fault: the boiler locks out if safe operation is no longer guaranteed, and our technician has to fix the cause.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F20?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F20
The meaning depends on the boiler: find yours below.
Combustion manager: Flame loss during the safety time / Solar EM: No volume flow
What our technician checks
- The gas supply pressure
- The ionisation electrode, replaced if needed
- The burner surface, cleaned or replaced, and clean combustion air
- The flue, its tightness and clear passage, and the condensate drain
- The start and ignition gas quantity settings (parameters 2.3.5 and 2.3.1), keeping the CO content in check
- The flue gas shut-off device and the gas valve unit, replaced if needed
- The solar pump, the flow sensor and venting the collector circuit (solar module)