Flame lost during operation
Blocking: it retries by itself
The burner flame goes out while the boiler is running. It is a warning: a one-off (strong wind at the flue outlet, for example) needs no action, but a Thermo Condens WTC-A tries to start again and locks out (F21) if that fails, and a WTC-OB locks out (F22) after 5 warnings.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show W22?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code W22
The meaning depends on the boiler: find yours below.
Flame loss during operation
Flame loss during operation (after 5 alarms, the system locks out…
What our technician checks
- The gas supply pressure
- The ionisation electrode (SCOT electrode on the WTC-A) and its cable, replaced if needed
- The burner surface, cleaned or replaced, and clean combustion air
- The flue, its tightness and clear passage, and the condensate drain
- The flue gas shut-off device, replaced if needed
- The oil supply, the oil pump and the nozzle (WTC-OB)
- The burner setting, mixing chamber, combustion tube and flame sensor (WTC-OB)