Temperature difference too large
Blocking: it retries by itself
The boiler stops because a temperature is out of range: the gap between flow water and flue gas is too large on a WTC-GW or WTC-GB B series boiler and a Thermo Condens WTC-A, the flue gas temperature rises too fast on a WTC-GW C series boiler, and the gap between flow and return water is too large on a WTC-OB. It is a warning that clears by itself, but if it keeps coming back the boiler locks out with code F15 (after several warnings on a B series, after 30 on a Thermo Condens WTC-A or a WTC-OB).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Do not reset the boiler: call us.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show W15?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code W15
The meaning depends on the boiler: find yours below.
Temperature differential flow/flue gas too large
Flue gas temp. rises too quickly (gradient)
Temperature difference between boiler temp. and flue gas too high
Difference between flow/return temperatures too high (after 30 alarms…
What our technician checks
- The water flow through the boiler, increased if needed
- The heat demand (heating curve), lowered if needed
- The maximum heating output (parameter 2.1.2 on the B series, 3.1.2 on the C series), reduced if too high