140

Dynamic pressure check failed

Breakdown: the boiler is stopped

On a Thision L Plus or Trigon L Plus, the dynamic check of the heating water pressure for burner 1 or 2 (the figure shown after the code) has failed, after the warning 1P9. This is a locking fault: the burner stays off until a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 140?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 140

The small number shown beside the code tells which.

140
1

Dynamic Pressure Check Failed

Breakdown: the boiler is stopped Thision L Plus, Trigon L Plus
140
2

Dynamic Pressure Check Failed

Breakdown: the boiler is stopped Thision L Plus, Trigon L Plus

What our technician checks

  • The system pressure, to be brought back between 1.5 and 2 bar, then venting
  • The water pressure sensor (P1) and the pressure read by the boiler (diagnostics 24.12.2)
  • The circulating pump: operation, noise, damage and leaks
  • The flow rate and modulation of the pump of the burner concerned (diagnostics 24.10 or 24.11)
  • The automatic air vent and the venting of the system
  • The system venting cycle (24.9.1)
  • The water connections: damage, corrosion and leaks

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.