Boiler temperature sensor fault
Breakdown: the boiler is stopped
The sensor that measures the water temperature in the boiler (boiler flow sensor) is short-circuited, open or faulty. The boiler goes to safety shutdown and stops heating; on a Trigon XL or Trigon XXL the fault clears by itself and the boiler restarts as soon as the sensor is plugged back in and working.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 20?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 20
The meaning depends on the boiler: find yours below.
Boiler temperature 1 sensor fault
Boiler temperature 1 sensor error
Boiler temperature sensor 1 fault
What our technician checks
- The boiler flow sensor (B2) and its plug: short or open circuit
- The sensor resistance, boiler switched off, against the maker's table (NTC 10 kΩ on a Trigon XXL)
- The test after repair: plug off gives code 20, plug back on and the boiler restarts