Elco Fault code Elco
20

Boiler temperature sensor fault

Breakdown: the boiler is stopped

The sensor that measures the water temperature in the boiler (boiler flow sensor) is short-circuited, open or faulty. The boiler goes to safety shutdown and stops heating; on a Trigon XL or Trigon XXL the fault clears by itself and the boiler restarts as soon as the sensor is plugged back in and working.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 20?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 20

The meaning depends on the boiler: find yours below.

20

Boiler temperature 1 sensor fault

Breakdown: the boiler is stopped Trigon XL
20

Boiler temperature 1 sensor error

Breakdown: the boiler is stopped Trigon XXL
20

Boiler temperature sensor 1 fault

Breakdown: the boiler is stopped Thision S Plus, Trigon S Plus

What our technician checks

  • The boiler flow sensor (B2) and its plug: short or open circuit
  • The sensor resistance, boiler switched off, against the maker's table (NTC 10 kΩ on a Trigon XXL)
  • The test after repair: plug off gives code 20, plug back on and the boiler restarts