Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Elco Fault code Elco
178

Heating circuit 1 limit thermostat

Breakdown: the boiler is stopped

The thermostat that limits the temperature of heating circuit 1 has tripped, and the controller is reporting it. On a Trigon XXL or a Trigon S Plus this code is one of the lockouts: the boiler stops and the cause must be removed before it is reset; on a Straton XL the controller reports a technical fault, which our technician has to fix.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. On a Trigon XXL or a Trigon S Plus, the boiler locks out: one reset is allowed.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.
  5. On a Straton XL, do not reset the boiler: the controller is reporting a technical fault.
  6. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 178?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 178

The meaning depends on the boiler: find yours below.

178

Limit thermostat heating circuit 1

Breakdown: the boiler is stopped Trigon XXL
178

Temperature controller heating circuit 1

Breakdown: the boiler is stopped Trigon S Plus
178

Thermostat HC1

Blocking: it retries by itself Straton XL

What our technician checks

  • The limit thermostat of heating circuit 1, its setting and the reason it tripped
  • The « heating circuit thermostat » function of input EX21 of the extension module (lines 6024 to 6028)
  • The voltage on input EX21, 0 V or 230 V, in the input test (lines 7950 to 7952)
  • The operation and setting of all connected safety devices
  • The software diagnostic code and the fault history (lines 6705 and 6800 onwards)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.