Buffer tank top temperature too high
Breakdown: the boiler is stopped
On a Thision L Plus or Trigon L Plus, the sensor at the top of the buffer tank reads a temperature that is too high. This is a locking fault: it stays on the display until a reset, and if it comes back our technician has to find the cause.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 731?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 731
The meaning depends on the boiler: find yours below.
Buffer High Probe Overtemperature
What our technician checks
- The temperature read by the top sensor (diagnostics 20.1.2)
- The buffer tank set points (menu 20.0)
- The buffer tank top sensor, its input on the boiler and its wiring
- Its resistance, measured with the boiler switched off and compared with the resistance table (NTC 10k)
- The buffer charging pump and the output that drives it