Repeated flame loss: retries used up
Breakdown: the boiler is stopped
On a Trigon S Plus, the flame has gone out during operation several times, until the number of allowed new attempts ran out (flame failure in operation repetition counter expired). It is a lockout: the warning symbol appears, the code flashes, and the boiler only restarts after a reset, once the cause has been removed.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 380?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 380
The meaning depends on the boiler: find yours below.
Repetition counter loss of flame during operation expired
What our technician checks
- The fault history (lines 6800 onward) and the software diagnostic code (line 6705), to find the recorded flame failures
- The ignition and ionisation electrode (wear, damage) and the ionisation current, above 4 µA at full output
- The dynamic gas pressure (17 to 25 mbar)
- The gas flow rate (plausibility check)
- The flue and air supply connections, clear and not reduced