Elco Fault code Elco
433

Primary heat exchanger too hot

Breakdown: the boiler is stopped

The temperature measured on the primary heat exchanger (sensor B26) is too high. On a Trigon XXL, a Thision S Plus or a Trigon S Plus this code is one of the lockouts: the boiler stops and the cause must be removed before it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 433?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 433

The meaning depends on the boiler: find yours below.

433

Temperature primary heat exchanger too high

Breakdown: the boiler is stopped Trigon XXL
433

Primary heat exchanger temperature too high

Breakdown: the boiler is stopped Thision S Plus, Trigon S Plus

What our technician checks

  • The water flow through the boiler, within the maker's limits
  • The pump operation and its direction of rotation
  • The sensor input the primary exchanger sensor B26 is assigned to (lines 5930 to 5933 on the boiler, 6040 to 6045 on the extension modules)
  • The temperature the controller reads on that input, in the input test (lines 7820 to 7835)
  • The operation and setting of all connected safety devices
  • The software diagnostic code and the fault history (lines 6705 and 6800 onwards)

Related codes