Elco Fault code Elco
173

Alarm contact H6 active

Breakdown: the boiler is stopped

The alarm contact on input H6 of the controller is active: an external device wired to that input is reporting a problem. On a Trigon XXL, a Thision S Plus or a Trigon S Plus this code is one of the lockouts: the boiler stops and the cause must be removed before it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 173?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 173

The meaning depends on the boiler: find yours below.

173

Alarm contact H6 active

Breakdown: the boiler is stopped Thision S Plus, Trigon S Plus, Trigon XXL

What our technician checks

  • The device wired to input H6 that raised the alarm, and the cause of that alarm
  • The state of contact H6 in the input test (line 7872)
  • The wiring of the contact to terminal H6 of the controller
  • The operation and setting of all connected safety devices
  • The software diagnostic code and the fault history (lines 6705 and 6800 onwards)