6
Control stop, temperature reached
Information: nothing to do
The water leaving for the heating is 5 °C above the requested temperature, so the burner stops for a while even though the heat demand continues. This is a normal control stop; on the Gas 210, 310 and 610 Eco it can also come from too large a difference between flow and return, or from the minimum time between two starts (Gas 210 Eco), and the boiler starts again by itself.
The variants of code 6
The meaning depends on the boiler: find yours below.
6
Flow temperature exceeds the programmed set point by 5°C
Information: nothing to do
Quinta 25/30s 28/35c, Quinta 45/65
6
Flow temperature > 5°C above the programmed set point (heating)
Information: nothing to do
Quinta 115, Quinta 85
6
Boiler stop (there is a heat demand but the boiler is not running
Information: nothing to do
Gas 210 Eco
6
Control stop (burner off + post-purge)
Information: nothing to do
Gas 310 Eco, Gas 610 Eco