Fault codes Oertli

Type the code your boiler shows: what it means, what you can do, and when a technician is needed.

The code is sometimes followed by a number (6A 227): the code is enough.

Your brand

Your boiler Oertli

The model is written on the rating plate, often under the cover.

All codes Oertli

#REVISION Boiler service due
AL 50 Boiler sensor fault
AL 52 Hot water sensor fault
AL tc Tank titanium anode: short circuit
AL td Tank titanium anode: open circuit
ANODE COURT-C. Tank corrosion protection short-circuited
ANODE DEBRANCH Tank corrosion protection disconnected
ANODE HS Tank corrosion protection out of order
ATTENDRE 2MN Water flow too low, burner off 2 minutes
B00 PSU circuit board wrongly configured
B01 Maximum flow temperature exceeded
B02 Flow temperature rising too fast
B07 Flow-return temperature difference too large
B08 RL input on the PCU board open
B09 Blocking message BL.INV. L/N
B10 BL input on the PCU board open
B11 BL input on the PCU board open
B13 Communication error with the SCU board
B14 Water pressure below 0.8 bar
B15 Gas pressure too low
B16 SU circuit board not recognised
B17 PCU board parameters corrupted
B18 PSU circuit board not recognised
B19 Boiler not configured
B21 Communication error between the PCU and SU boards
B22 Flame lost during operation
B25 Internal fault in the SU board
BL. AIR Blocking: parameters set wrongly
BL.DT CHA.RET. Blocking: flow and return gap too large
BL.FUMEE Blocking: flue gas too hot
BL.INT.MCBA Blocking: control box settings or memory
BL.RET.SUP.CHA Blocking: return hotter than flow
BL.VENTIL.OFF Blocking: fan faulty or badly fitted
BL.VENTIL.ON Fan still running after post-purge
BL.VITESSE T. Blocking: flow temperature rising too fast
BLOQUANT b26 Blocking: external safety contact open
BLOQUANT bXX Blocking: safety control box stopped
COURT-CIRC.24V Short circuit on the 24 V circuit
D03 Circuit B flow sensor fault
D04 Circuit C flow sensor fault
D05 Outdoor temperature sensor fault
D07 Auxiliary sensor fault
D09 Hot water sensor fault
D11 Room sensor A fault
D12 Room sensor B fault
D13 Room sensor C fault
D14 Lost link with the radio boiler module
D15 Buffer tank sensor fault
D16 Swimming pool sensor fault
D17 Hot water tank 2 sensor fault
D27 Lost communication between SCU and PCU boards
D29 Lost link with circuit B valve module
D30 Lost link with circuit C valve module
D31 The IOBL function is no longer active
D32 Five resets in less than an hour
D37 Titan Active System anode short circuit
D38 Titan Active System anode circuit open
DEF. S.AMB.A Room sensor A fault
DEF. S.AMB.B Room sensor B fault
DEF. S.AMB.C Circuit C room sensor fault
DEF. S.CHAUD Boiler temperature sensor fault
DEF. S.DEP.B Circuit B flow sensor fault
DEF. S.DEP.C Circuit C flow sensor fault
DEF. S.ECS Hot water sensor fault
DEF. S.EXT. Outdoor temperature sensor fault
DEF. S.FUMEE Flue gas sensor fault
DEF. VENTILO Burner fan fault
DEF.ALLUMAGE Boiler ignition fault
DEF.COM.CVI Lost communication with the safety box
DEF.COM.MCBA No communication with the safety control box
DEF.IONISATION Flame signal lost while running
DEF.MANOMETRE Water pressure sensor fault
DEF.S.BAL.TP Buffer tank sensor fault
DEF.S.PISCINE Swimming pool sensor fault
DEF.S.RETOUR Return temperature sensor fault
DEF.S.SOLAIRE Solar sensor fault
DEF.VANNE GAZ Burner gas valve fault
DEF.VENTIL.OFF Fan not turning
DEF.VENTIL.ON Fan running all the time
DEFAUT CVI10-22 Internal fault in the burner safety box
DEFAUT CVI8 Ignition electrode badly positioned
DEFAUT CVI9 Gas valve control fault
DEFAUT MCBA 11 Safety control box: internal fault 11
DEFAUT MCBA 24 Boiler and return sensors swapped
DEFAUT MCBA 5 Safety control box: external interference
DEFAUT MCBA XX Internal fault in the safety control box
E00 Flow or return sensor fault
E01 Flow temperature too high
E02 Return warmer than flow
E03 Control panel or power cable faulty
E04 No flame detected at start-up
E05 Flame ionisation fault
E06 Unwanted flame detected
E07 Low water or pump not running
E08 Boiler fan fault
E10 No water flow during a fan cycle
E11 Sealed air box too hot
E12 Heat recovery unit fault
E13 Heat exchanger thermal fuse tripped
E43 Parameters out of limits
E44 Parameter check failed
E45 Factory settings error
FLAM.PARASI. Stray flame detected
IIII■ Burner lockout: air pressure switch opened
III■■ Burner lockout: air switch or oil preheater
II■■■ Burner lockout: stray flame or light
I■■■■ Burner lockout: no flame
L00 PSU circuit board not connected
L01 Safety parameters incorrect
L02 Flow sensor short-circuited
L03 Flow sensor open circuit
L04 Boiler temperature too low
L05 Boiler temperature too high
L06 Return sensor short-circuited
L07 Return sensor open circuit
L08 Return temperature too low
L09 Return temperature too high
L10 Flow-return difference too small
L11 Flow-return difference too large
L12 Overheating, STB maximum thermostat open
L14 Five failed burner starts
L16 Stray flame detected
L17 Gas valve problem
L250 Water pressure too low
L251 Water pressure sensor fault
L34 Fan not running at the right speed
L35 Flow and return reversed
L36 Repeated flame loss within 24 hours
L37 Communication with the SU board lost
L38 Communication between the PCU and SCU boards lost
L39 BL input briefly opened
L40 HRU/URC unit test failed
M04 Boiler service due
M05 Type A service due
M06 Type B service due
M07 Type C service due
M20 Automatic air purge in progress
M23 Wireless outdoor sensor to be replaced
MANQUE EAU Water pressure too low
PAS DE CONF. Boiler configuration not recognised
PURGE Hot water heat exchanger purge running
REARMER Boiler needs a reset
SECT. FAIBLE Mains voltage too low
STB CHAUD. Overheating: safety thermostat tripped
STB FUMEE Flue gas too hot: safety limiter tripped
STB RETOUR Return temperature too high
VOIR CAD Override active on a remote control
05 Blocking time of 3 to 10 minutes
08 Standby: flow temperature reached
09 Boiler temporarily blocked