Fault code Oertli
D31

The IOBL function is no longer active

Breakdown: the boiler is stopped

On a GMR 3000 or GMR 5000 Condens, the IOBL function, which links the controller to connected modules (V3V IOBL module, Interscenario switch), no longer works, because of a problem on the SCU circuit board. It is a fault: the control panel flashes and shows the code, and our technician needs to switch the function off if it is not used, or replace the board.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show D31?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code D31

The meaning depends on the boiler: find yours below.

D31

The IOBL function is no longer active

Breakdown: the boiler is stopped GMR 3000 Condens, GMR 5000 Condens

The boilers that show this code

What our technician checks

  • The IOBL function, to be switched off if not used (#CONFIGURATION menu, or parameter S18 on an OE-control panel)
  • The SCU circuit board, to be replaced if the IOBL function is used, then pairing the devices again (V3V IOBL module, Interscenario switch)