Fault code Oertli
B02

Flow temperature rising too fast

Blocking: it retries by itself

The temperature of the water leaving for the heating rises beyond the permitted limit, because the water is not flowing enough through the system or because of a sensor. On the GMR 3000 and GMR 5000 Condens it is a blocking message: the boiler stops and starts again by itself once the cause is gone.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the radiator valves are open.
  3. Check the water pressure on the display: below 0.8 bar, top up with water as the user manual explains (recommended pressure 1.5 to 2.0 bar).
  4. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show B02?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code B02

The meaning depends on the boiler: find yours below.

B02

The rise of the flow temperature has exceeded its maximum limit

Blocking: it retries by itself GMR 3000 Condens, GMR 5000 Condens

The boilers that show this code

What our technician checks

  • Water circulation: direction, pump and valves
  • The system water pressure
  • How clean the heat exchanger is
  • Operation of the sensors and how the boiler sensor is fitted

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.