Flow-return temperature difference too large
Blocking: it retries by itself
The difference between the temperature of the water leaving for the heating and the water coming back has gone above its maximum, because the water is not flowing enough through the system or because of a sensor. On the GMR 3000 and GMR 5000 Condens it is a blocking message: the boiler stops and starts again by itself once the cause is gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the radiator valves are open.
- Check the water pressure on the display: below 0.8 bar, top up with water as the user manual explains (recommended pressure 1.5 to 2.0 bar).
- Does the code stay on or come back? Do not take anything apart: call us.