Return warmer than flow
Breakdown: the boiler is stopped
On a GMR 1000 Condens, the water coming back to the boiler (return) is warmer than the water leaving it (flow), for example because the water pressure is too low, the water is not circulating, there is too much air, or a sensor is badly connected or reads wrongly. The boiler stops and the code flashes on the display; it only restarts after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the water pressure on the boiler's pressure gauge: below 1 bar, top up the water as your installer showed you.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E02?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E02
The meaning depends on the boiler: find yours below.
Return temperature > flow temperature
The boilers that show this code
What our technician checks
- The system water pressure (pressure gauge)
- The boiler circulation pump: shaft freed with a screwdriver, wiring, replaced if it does not run
- Bleeding the boiler, with the pump off
- The wiring between the sensors and the control panel
- The flow and return sensors: operation and resistance with a multimeter (12 to 15 kOhm at 20 to 25 °C)