Fault code Oertli
E00

Flow or return sensor fault

Breakdown: the boiler is stopped

On a GMR 1000 Condens, the flow or return temperature sensor is short-circuited, faulty, or not or badly connected. The boiler stops and the code flashes on the display; it only restarts after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E00?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E00

The meaning depends on the boiler: find yours below.

E00

Flow or return sensor fault

Breakdown: the boiler is stopped GMR 1000 Condens

The boilers that show this code

What our technician checks

  • The sensor wiring, with the protective caps put back
  • The flow and return sensors: operation and resistance with a multimeter (12 to 15 kOhm at 20 to 25 °C)