Flow or return sensor fault
Breakdown: the boiler is stopped
On a GMR 1000 Condens, the flow or return temperature sensor is short-circuited, faulty, or not or badly connected. The boiler stops and the code flashes on the display; it only restarts after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E00?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E00
The meaning depends on the boiler: find yours below.
Flow or return sensor fault
The boilers that show this code
What our technician checks
- The sensor wiring, with the protective caps put back
- The flow and return sensors: operation and resistance with a multimeter (12 to 15 kOhm at 20 to 25 °C)