Boiler temporarily blocked
Blocking: it retries by itself
On a GMR 1000 Condens, the boiler has stopped for a while (block): water too hot or heating up too fast, more than 45 °C between flow and return, water not circulating or pressure too low, or a blocking input open. It tries to restart by itself after about 10 minutes.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the water pressure on the boiler's pressure gauge: below 1 bar, top up the water as your installer showed you.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 09?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 09
The meaning depends on the boiler: find yours below.
Lock-out
The boilers that show this code
What our technician checks
- The boiler maximum temperature and how fast the flow temperature rises (over 1 °C per second)
- The flow to return difference (over 45 °C)
- Circulation, water level and pressure
- The bridge on terminals 5 and 6 of connector X9 (blocking input)