Flow-return difference too large
Breakdown: the boiler is stopped
The difference between the temperature of the water leaving for the heating and the water coming back is too large, because of a faulty sensor, a bad connection or water that is not circulating. On the GMR 3000 and GMR 5000 Condens it is a fault: the control panel flashes and the boiler stays off until it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the radiator valves are open, then bleed the air from the cold radiators, starting with the lowest floors.
- Check the water pressure on the display: below 0.8 bar, top up with water as the user manual explains (recommended pressure 1.5 to 2.0 bar).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show L11?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code L11
The meaning depends on the boiler: find yours below.
Difference between flow and return temperatures too large
The boilers that show this code
What our technician checks
- The resistance value and fitting of the sensors, replaced if needed
- Bleeding the air from the heating system
- Water circulation: direction, pump and valves
- The system water pressure
- How clean the heat exchanger is
- Correct operation of the heating pump