Fault code Oertli
D30

Lost link with circuit C valve module

Breakdown: the boiler is stopped

On a GMR 3000 or GMR 5000 Condens, the control board (SCU) no longer communicates with the 3-way valve module (V3V IOBL module) of circuit C: the module has no power, is not on the same electrical phase as the board, or was removed. It is a fault: the control panel flashes and shows the code, and our technician needs to restore the link.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show D30?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code D30

The meaning depends on the boiler: find yours below.

D30

Communication lost between the SCU board and the 3-way valve module

Breakdown: the boiler is stopped GMR 3000 Condens, GMR 5000 Condens

The boilers that show this code

What our technician checks

  • Power to the V3V module (green LED on)
  • The V3V module and the SCU board on the same phase, or a phase coupler fitted
  • If the V3V module was removed on purpose, erasing it from the SCU board memory

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.