Burner lockout: air switch or oil preheater
Breakdown: the boiler is stopped
On a gas burner with a DMG box, the air pressure switch did not close in time (III■■) or its contact stayed stuck in the working position (■■III); on an oil burner with a DKO 996 box (OEN, OPN or OCN 160 LEV), III■■ means the oil preheater did not close its contact within 400 seconds. In every case the burner has locked out and stays off until it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show III■■?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code III■■
The meaning depends on the boiler: find yours below.
Air pressure switch time-out.
The preheater contact does not close within 400 s
Air pressure switch in working position.
What our technician checks
- The air pressure switch and its wiring, replaced if faulty (DMG)
- The pressure tube to the air pressure switch, cleaned or reconnected (DMG)
- The oil preheater, nozzle line replaced if faulty (DKO 996)
- The control and safety box, replaced if it stays locked out after the first reset