Burner lockout: stray flame or light
Breakdown: the boiler is stopped
The burner box saw a flame or light when there should be none: a residual flame on a gas burner with a DMG box (II■■■), stray light or a faulty cell on an oil burner with a DKO 972, 976, 992 or 996 box (II■■■), a flame still present at the end of the pre-purge on a DKO 992 (■■■II). Followed by a long pause and long pulses (II■■■--■■■■■ on a DMG, II■■■--■■■■ on a DKO 976), the code instead means a manual or external lockout; in every case the burner stays off until it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show II■■■?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code II■■■
The meaning depends on the boiler: find yours below.
Residual flame.
Stray light during pre-purge
Stray light
Manual or external lockout
Manual or external lockout.
Flame presence test
What our technician checks
- The ionisation probe, its position and adjustment, replaced if faulty (DMG)
- The flame detection cell and its leads, replaced if faulty (DKO)
- The source of stray light reaching the cell during pre-purge (DKO)
- The external fault that locked out the box (code with a long pause)
- The control and safety box, replaced if it stays locked out after the first reset