Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Fault code Oertli
D37

Titan Active System anode short circuit

Breakdown: the boiler is stopped

On a GMR 3000 or GMR 5000 Condens, the Titan Active System anode that protects the hot water tank is short-circuited. Hot water production is stopped and the tank is no longer protected; the control panel flashes and shows the code.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.
  4. While waiting for our technician, you can restart hot water with the hot water key on the control panel.

Does your boiler show D37?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code D37

The meaning depends on the boiler: find yours below.

D37

The Titan Active System® is short-circuited

Breakdown: the boiler is stopped GMR 3000 Condens, GMR 5000 Condens

The boilers that show this code

What our technician checks

  • The connecting cable between the SCU board and the anode (short circuit)
  • The anode (short circuit)
  • On a tank without Titan Active System, the dummy connector (kit AD212) fitted on the sensor board

Related codes