Fault code Oertli
E04

No flame detected at start-up

Breakdown: the boiler is stopped

On a GMR 1000 Condens, the boiler detects no flame after its start attempts (up to 5 after a long shutdown): no spark at the electrode, sparks but no flame, or a flame with too weak an ionisation current. The boiler stops and the code flashes on the display; it only restarts after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas tap is open.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E04?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E04

The meaning depends on the boiler: find yours below.

E04

No flame detected

Breakdown: the boiler is stopped GMR 1000 Condens

The boilers that show this code

What our technician checks

  • The ignition electrode: gap (3.5 mm), connector and lead
  • The earth connection
  • The gas tap, the supply pressure and purging of the gas line
  • The air and flue duct (not blocked, not leaking) and the condensate trap (full, not blocked)
  • The mains connection, or an isolating transformer
  • The ignition electrodes, cleaned or replaced
  • Combustion, flame stability and the CO2 level at low and high fan speed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.