No flame detected at start-up
Breakdown: the boiler is stopped
On a GMR 1000 Condens, the boiler detects no flame after its start attempts (up to 5 after a long shutdown): no spark at the electrode, sparks but no flame, or a flame with too weak an ionisation current. The boiler stops and the code flashes on the display; it only restarts after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E04?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E04
The meaning depends on the boiler: find yours below.
No flame detected
The boilers that show this code
What our technician checks
- The ignition electrode: gap (3.5 mm), connector and lead
- The earth connection
- The gas tap, the supply pressure and purging of the gas line
- The air and flue duct (not blocked, not leaking) and the condensate trap (full, not blocked)
- The mains connection, or an isolating transformer
- The ignition electrodes, cleaned or replaced
- Combustion, flame stability and the CO2 level at low and high fan speed