Fault code Oertli
L36

Repeated flame loss within 24 hours

Breakdown: the boiler is stopped

While the burner was running, the flame went out more than 5 times in 24 hours: the boiler no longer measures an ionisation current, the signal that confirms the flame. On the GMR 3000 and GMR 5000 Condens it is a fault: the control panel flashes and the boiler stays off until it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas tap is open.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show L36?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code L36

The meaning depends on the boiler: find yours below.

L36

The flame went out more than 5 times in 24 hours while the burner was running

Breakdown: the boiler is stopped GMR 3000 Condens, GMR 5000 Condens

The boilers that show this code

What our technician checks

  • Purging the gas line
  • The gas tap and the gas supply pressure
  • Operation and setting of the gas valve unit
  • The air intake and flue gas ducts (blockage)
  • Any flue gas recirculation

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.