Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Fault code Oertli
DEF. S.ECS

Hot water sensor fault

Blocking: it retries by itself

The hot water sensor (Dutch-language message: GEBREK SWW V.) is cut, short-circuited or faulty. On a GMR 4000 or GSR 140-35 P to 140-115 Condens, hot water heating is no longer ensured and the tank is charged at the boiler temperature; on a GSR 140-15 P, GSR 140-25 P or GVR 140 Condens, or a PK 150, PU 150, CU 150 or PK 260 with control panel R, hot water is only ensured in manual mode.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show DEF. S.ECS?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code DEF. S.ECS

The meaning depends on the boiler: find yours below.

DEF. S.ECS

The corresponding sensor is open or short-circuited.

Blocking: it retries by itself GSR 140-25 P Condens
DEF. S.ECS

Domestic hot water sensor faulty

Blocking: it retries by itself GMR 4000 Condens
DEF. S.ECS

The sensor concerned is cut or short-circuited.

Blocking: it retries by itself PK/PU/CU 150

The boilers that show this code

What our technician checks

  • The sensor wiring and connectors
  • The sensor, replaced if needed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.