Fault code Oertli
D04

Circuit C flow sensor fault

Breakdown: the boiler is stopped

The sensor that measures the flow temperature of heating circuit C is faulty, because of a bad connection or a faulty sensor. On the GMR 3000 and GMR 5000 Condens it is a fault: the control panel flashes; the circuit C pump keeps running, but the motor of its 3-way valve is no longer powered.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show D04?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code D04

The meaning depends on the boiler: find yours below.

D04

Circuit C flow sensor fault

Breakdown: the boiler is stopped GMR 3000 Condens, GMR 5000 Condens

The boilers that show this code

What our technician checks

  • Whether the sensor is connected (clearing the sensors from the board memory if it was removed)
  • The link and the connectors
  • How the sensor is fitted
  • The sensor's resistance value, replaced if needed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.