Outdoor temperature sensor fault
Blocking: it retries by itself
The outdoor sensor (Dutch-language message: GEBREK BUIT.V.) is cut, short-circuited or faulty: the boiler keeps heating, hot water stays available and the maximum temperature of the valve circuits is still monitored. On a GSR 140-15 P, GSR 140-25 P or GVR 140 Condens, or a PK 150, PU 150, CU 150 or PK 260 with control panel R, the boiler switches to manual mode and its valves are no longer regulated; on a GMR 4000 or GSR 140-35 P to 140-115 Condens, it heats at its set maximum temperature and the 3-way valve of circuit B, if any, is no longer regulated.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show DEF. S.EXT.?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code DEF. S.EXT.
The meaning depends on the boiler: find yours below.
The corresponding sensor is open or short-circuited.
Fault of the corresponding sensor
The sensor concerned is cut or short-circuited.
The boilers that show this code
What our technician checks
- The sensor wiring and connectors
- The sensor, replaced if needed
- A short power cut with the on/off switch to clear the message (GMR 4000, GSR 140-35 P to 140-115)
- Manual mode on the affected part of the system until the repair (GMR 4000, GSR 140-35 P to 140-115)
Related codes
From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.