+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Fault code Oertli
DEF.ALLUMAGE

Boiler ignition fault

Breakdown: the boiler is stopped

On a GSR 140-15 P, GSR 140-25 P, GVR 140, GMR 4000 or GSR 140-35 P to 140-115 Condens (Dutch-language message: GEB. ONTST.), the burner does not light or the flame is not detected: ignition fault, ionisation fault, faulty gas valve, or no gas or air in the pipe. The boiler locks out for safety and only restarts after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show DEF.ALLUMAGE?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code DEF.ALLUMAGE

The meaning depends on the boiler: find yours below.

DEF.ALLUMAGE

Ignition fault / Ionisation fault / Gas valve faulty

Breakdown: the boiler is stopped GMR 4000 Condens, GSR 140-25 P Condens

The boilers that show this code

What our technician checks

  • The ignition electrode: gap, connector and lead, replaced if needed
  • The earth connection and the ionisation current
  • The CO2 level, corrected if needed
  • The gas valve, replaced if faulty
  • The gas supply pressure and purging of the gas line

Related codes