Boiler ignition fault
Breakdown: the boiler is stopped
On a GSR 140-15 P, GSR 140-25 P, GVR 140, GMR 4000 or GSR 140-35 P to 140-115 Condens (Dutch-language message: GEB. ONTST.), the burner does not light or the flame is not detected: ignition fault, ionisation fault, faulty gas valve, or no gas or air in the pipe. The boiler locks out for safety and only restarts after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show DEF.ALLUMAGE?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code DEF.ALLUMAGE
The meaning depends on the boiler: find yours below.
Ignition fault / Ionisation fault / Gas valve faulty
The boilers that show this code
What our technician checks
- The ignition electrode: gap, connector and lead, replaced if needed
- The earth connection and the ionisation current
- The CO2 level, corrected if needed
- The gas valve, replaced if faulty
- The gas supply pressure and purging of the gas line
Related codes
From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.