Fault code Oertli
L12

Overheating, STB maximum thermostat open

Breakdown: the boiler is stopped

The boiler's maximum temperature has been exceeded and its maximum safety thermostat (STB) has opened, because of a bad connection, a faulty sensor or water that is not circulating. On the GMR 3000 and GMR 5000 Condens it is a fault: the control panel flashes and the boiler stays off until it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the radiator valves are open, then bleed the air from the cold radiators, starting with the lowest floors.
  3. Check the water pressure on the display: below 0.8 bar, top up with water as the user manual explains (recommended pressure 1.5 to 2.0 bar).
  4. Reset the boiler once only.
  5. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show L12?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code L12

The meaning depends on the boiler: find yours below.

L12

Maximum boiler temperature exceeded (STB maximum thermostat)

Breakdown: the boiler is stopped GMR 3000 Condens, GMR 5000 Condens

The boilers that show this code

What our technician checks

  • The wiring between the PCU board and the STB, and the seating of the SU board
  • The STB's electrical continuity and fitting, replaced if needed
  • Bleeding the air from the heating system
  • Water circulation: direction, pump and valves
  • The system water pressure
  • How clean the heat exchanger is