Fault code Oertli
L14

Five failed burner starts

Breakdown: the boiler is stopped

The burner has failed to start 5 times: no ignition spark, a spark without a flame, or a flame that is poorly detected (ionisation current too low). On the GMR 3000 and GMR 5000 Condens it is a fault: the control panel flashes and the boiler stays off until it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas tap is open.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show L14?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code L14

The meaning depends on the boiler: find yours below.

L14

5 failed burner starts

Breakdown: the boiler is stopped GMR 3000 Condens, GMR 5000 Condens

The boilers that show this code

What our technician checks

  • The wiring between the PCU board and the ignition transformer
  • The ionisation and ignition electrode and its wiring
  • The earthing
  • Purging the gas lines
  • The gas tap and the gas supply pressure
  • The gas valve unit: operation, setting and wiring
  • The air intake and flue gas ducts (blockage)
  • The SU board, correctly seated, changed if faulty