Tank titanium anode: open circuit
Blocking: it retries by itself
The titanium anode that protects the hot water tank against corrosion is an open circuit, or the tank is empty. Hot water production has stopped and the tank is no longer protected against corrosion: call us.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Until we come, you can restart the hot water for 24 hours by switching the boiler off and on again.
- Call us in any case: the tank is no longer protected against corrosion.
Does your boiler show AL td?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code AL td
The meaning depends on the boiler: find yours below.
Titanium anode
The boilers that show this code
What our technician checks
- The titanium anode connection
- Filling the tank with water (empty tank)
- On a tank with a magnesium anode, the AD212 kit plug (22 kOhm resistor, 100 nF capacitor) on terminals 25-26
Related codes