Fault code Oertli
L04

Boiler temperature too low

Breakdown: the boiler is stopped

The boiler measures a temperature that is too low, because of a bad connection, a faulty sensor or water that is not circulating. On the GMR 3000 and GMR 5000 Condens it is a fault: the control panel flashes and the boiler stays off until it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the radiator valves are open, then bleed the air from the cold radiators, starting with the lowest floors.
  3. Check the water pressure on the display: below 0.8 bar, top up with water as the user manual explains (recommended pressure 1.5 to 2.0 bar).
  4. Reset the boiler once only.
  5. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show L04?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code L04

The meaning depends on the boiler: find yours below.

L04

Boiler temperature too low

Breakdown: the boiler is stopped GMR 3000 Condens, GMR 5000 Condens

The boilers that show this code

What our technician checks

  • The wiring between the PCU board and the sensor
  • Correct seating of the SU board
  • How the sensor is fitted
  • The sensor's resistance value, sensor replaced if needed
  • Bleeding the air from the heating system
  • Water circulation: direction, pump and valves
  • The system water pressure
  • How clean the heat exchanger is

Related codes