Fault code Oertli
D05

Outdoor temperature sensor fault

Breakdown: the boiler is stopped

On a GMR 3000 or GMR 5000 Condens, the controller no longer gets a valid reading from the outdoor sensor, because of a bad connection or a faulty sensor. The boiler keeps heating, at its set maximum temperature, and hot water stays available; the circuit valves are no longer regulated, but the maximum temperature of the valve circuits is still monitored.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show D05?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code D05

The meaning depends on the boiler: find yours below.

D05

Outdoor sensor fault

Breakdown: the boiler is stopped GMR 3000 Condens, GMR 5000 Condens

The boilers that show this code

What our technician checks

  • The sensor connection; if it was removed on purpose, erasing it from the SCU board memory
  • The sensor wiring and connectors
  • How the sensor is fitted
  • The sensor's resistance (ohms), replaced if needed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.