Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Fault code Oertli
B17

PCU board parameters corrupted

Blocking: it retries by itself

The parameters stored in the boiler's PCU circuit board are corrupted. On the GMR 3000 and GMR 5000 Condens it is a blocking message: the boiler stops and only starts again by itself once the cause is gone, here a board replaced by our technician.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show B17?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code B17

The meaning depends on the boiler: find yours below.

B17

The parameters stored on the PCU board are corrupted

Blocking: it retries by itself GMR 3000 Condens, GMR 5000 Condens

The boilers that show this code

What our technician checks

  • The PCU board, to be replaced

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.