Gas valve leak test failed
Blocking: it retries by itself
At start-up, the gas leak test (VPS) checks the safety valves of the gas valve block, and this test has failed: no or too little gas pressure, a gas valve that leaks or stays open, a wrongly set VPS switch, the wiring, or a faulty leak tester. On the Gas 210 Eco Pro and Gas 310/610 Eco Pro it is a blocking code: the boiler stays off and starts again by itself if the cause disappears; on the Gas 210 Eco Pro, after five failed tests, it locks out (code E:15).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show Su:24?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code Su:24
The meaning depends on the boiler: find yours below.
VPS test incorrect
Gas leak tester fault
What our technician checks
- The gas tap, fully open, and the gas pressure
- Fitting and setting of the VPS switch
- The gas valve: leaking or staying open
- The wiring, including swapped V1 and V2 plugs
- The VPS leak tester and the gas valve block, replaced if needed