Flow temperature below the minimum
Breakdown: the boiler is stopped
The temperature of the water leaving the boiler for the heating (the flow) is below the permitted minimum; on the Avanta Ace the flow sensor may also be disconnected. The boiler locks out for safety and stays off until it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E04.18?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E04.18
The meaning depends on the boiler: find yours below.
The flow temperature is below the minimum temperature or the
Min flow T error
The flow temperature is below the minimum temperature
What our technician checks
- The connection of the flow sensor to the circuit board
- The sensor: operation checked, replaced if faulty
- How the sensor is fitted on the flow pipe