Return too hot or no water
Breakdown: the boiler is stopped
This code does not mean the same on every boiler: on a Calenta, Tzerra M, Quinta Pro or Gas 210 Eco Pro (E:09), the return water temperature is too high, because of a badly connected or faulty sensor or water that is not circulating; on an Avanta Plus or Avanta Platinum Plus (E09), there is not enough water in the boiler (pressure below 0.6 bar) or the water pressure sensor is faulty. In both cases the boiler locks out and stays off until the cause is removed and it is reset (on a Tzerra M, which has no display, the light on the button then flashes red).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- On a Calenta, Tzerra M or Quinta Pro: check the water pressure. Above 0.8 bar, bleed the radiators; below it, top up with water to about 1.5 bar as the user manual explains.
- On an Avanta Plus or Avanta Platinum Plus: check the water pressure; below 1 bar, top up with water as the user manual explains.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E:09?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E:09
The meaning depends on the boiler: find yours below.
No water in the boiler
Return temperature too high
Return temperature above the normal range (maximum thermostat)
The boilers that show this code
What our technician checks
- The return sensor's wiring and fitting, replaced if needed (E:09)
- Circulation (direction, pump, valves), bleeding and water pressure (E:09)
- How clean the heat exchanger is, and the boiler type parameter (E:09)
- Any water leaks and the expansion vessel (E09)
- Refilling with clean tap water (1.5 to 2 bar), then bleeding (E09)
- The water pressure sensor, replaced if faulty (E09)