Flow temperature rising too fast
Blocking: it retries by itself
The water leaving the boiler for the heating warms up faster than allowed, most often because too little water is flowing, sometimes because of a sensor. On the Calenta, Tzerra M and Quinta Pro it is a blocking code: the boiler stops and starts again by itself once the cause is gone (on the Tzerra M, the status light on the button flashes green once).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the system water pressure: at least 0.8 bar. Too low? Top up with water as your installer showed you.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show Su:2?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code Su:2
The meaning depends on the boiler: find yours below.
Maximum rise of the flow temperature exceeded
The boilers that show this code
What our technician checks
- Water circulation: direction, pump and valves
- The system water pressure
- Fouling of the heat exchanger
- Operation and fitting of the sensors