Heat exchanger to flow difference too high
Blocking: it retries by itself
The temperature difference between the boiler's heat exchanger and the flow water to the heating has gone above its maximum, because of no or too little water flow in the system, or a sensor error. On the Quinta 45-115, Gas 210 Ace, Gas 220 Ace and Gas 320/620 Ace it is a blocking message: the boiler stops normal operation and starts again by itself once the cause is gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the system water pressure: below 0.8 bar, top up with water as the user manual explains (recommended pressure 1.5 to 2.0 bar).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show H.01.06?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H.01.06
The meaning depends on the boiler: find yours below.
Delta TECHT-Max flow T
What our technician checks
- Water circulation: direction, pump and valves
- The system water pressure
- How clean the heat exchanger is
- Whether the system has been bled of air
- Water quality, against the supplier's specifications
- Operation of the sensors and how they are fitted