Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Remeha Fault code Remeha
E04.03

Maximum flow temperature exceeded

Breakdown: the boiler is stopped

The boiler's flow water has exceeded its maximum safety temperature, because the water does not circulate or too little (pressure, air, pump, valves) or because of a sensor; on the Avanta Ace the same code also reports a short-circuited flow sensor. On the Calenta Ace, Tzerra Ace, Quinta Ace, Quinta 45-115, Gas 210 Ace, Gas 220 Ace, Gas 320/620 Ace, Calenta Ace-Matic, Tzerra Ace-Matic and Avanta Ace it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check the system's water pressure: below 0.8 bar, top up with water as the user manual explains.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E04.03?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E04.03

The meaning depends on the boiler: find yours below.

E.04.03

Maximum flow temperature exceeded or flow temperature sensor short-circuited

Breakdown: the boiler is stopped Avanta Ace
E.04.03

Max flow T

Breakdown: the boiler is stopped Gas 210 Ace, Gas 220 Ace, Gas 320/620 Ace, Quinta 45-115
E04.03

Maximum flow temperature exceeded

Breakdown: the boiler is stopped Calenta Ace-Matic, Tzerra Ace-Matic
E04.03

Flow temp limit

Breakdown: the boiler is stopped Calenta Ace
E04.03

Flow temperature is above the maximum

Breakdown: the boiler is stopped Tzerra Ace
E04.03

Max flow T

Breakdown: the boiler is stopped Quinta Ace

What our technician checks

  • Circulation: direction, pump and valves
  • The system's water pressure
  • Bleeding the air out of the system
  • Whether the heat exchanger is clean
  • The sensors' operation and fitting

Related codes