Flow and return temperature gap too large
Blocking: it retries by itself
The difference between the temperature of the water going out to the heating and that of the water coming back has reached its maximum, for example because the water is not circulating enough. It is a temporary block: the boiler stops and starts again by itself once the cause is gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the water pressure shown: if it is below 0.8 bar, top up the system with water as the user manual explains.
- Check that the radiator valves are open.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show H01.05?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H01.05
The meaning depends on the boiler: find yours below.
Maximum temperature difference between the flow temperature and the
Max delta flow-return T
Maximum temperature difference between the flow temperature and the
Delta TF-TR max
Maximum difference between the flow temperature and the return temperature
What our technician checks
- Water circulation: direction, pump and valves
- The system water pressure
- Bleeding the air out of the system
- The heat exchanger for fouling
- How the temperature sensors work and are fitted
- The temperature sensor connections