SMI closed and minimum positions together
Breakdown: the boiler is stopped
On the Gas 210 Eco, the boiler detects the closed position and the minimum position of the flag of its air/gas mixing system (SMI) at the same time, which is impossible: a flag setting, the wiring or the SMI circuit board is at fault. The boiler goes into lockout (the digits flash) and only restarts after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 93?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 93
The meaning depends on the boiler: find yours below.
Simultaneous detection of the minimum position and the closed position of the SMI
What our technician checks
- The setting of the SMI 0 % and minimum flags, which must not both be in the light barrier
- The SMI wiring and connectors
- The SMI circuit board, replaced if everything else is in order