Remeha Fault code Remeha
93

SMI closed and minimum positions together

Breakdown: the boiler is stopped

On the Gas 210 Eco, the boiler detects the closed position and the minimum position of the flag of its air/gas mixing system (SMI) at the same time, which is impossible: a flag setting, the wiring or the SMI circuit board is at fault. The boiler goes into lockout (the digits flash) and only restarts after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 93?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 93

The meaning depends on the boiler: find yours below.

93

Simultaneous detection of the minimum position and the closed position of the SMI

Breakdown: the boiler is stopped Gas 210 Eco

What our technician checks

  • The setting of the SMI 0 % and minimum flags, which must not both be in the light barrier
  • The SMI wiring and connectors
  • The SMI circuit board, replaced if everything else is in order