External safety device tripped
Breakdown: the boiler is stopped
On the Quinta 25, 30 and 115 and the Gas 210, 310 and 610 Eco, an external safety device connected to the boiler (for example a safety thermostat) has tripped, its wire bridge has been removed or a fuse of the control is faulty. On the W40-m and W60-m Eco this code reports a fault of the control unit (fuse): in both cases the boiler goes into lockout (the digits flash) and only restarts after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 12?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 12
The meaning depends on the boiler: find yours below.
External safety device
External safety input
Lockout input open
Control unit fault
What our technician checks
- The external safety device on the terminal strip and its wire bridge (Quinta: terminals 10 and 14, Gas 210 Eco: terminals 1 and 2, Gas 310 and 610 Eco: X29-1 and X29-2)
- The control unit fuses (F2 on the Quinta and the Gas 210 Eco, F3 on the Gas 310 and 610 Eco, F1 on the W40-m and W60-m Eco)