Live and neutral reversed
Blocking: it retries by itself
The boiler detects that the live and neutral of its power supply are reversed: the supply is wrongly wired, or the network is floating or two-phase. On the Calenta, Quinta Pro, Gas 210 Eco Pro and Gas 310/610 Eco Pro it is a blocking code: the boiler stays off and starts again by itself once the cause is gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show Su:9?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code Su:9
The meaning depends on the boiler: find yours below.
Phase and neutral of the mains voltage reversed
Phase and neutral of the supply voltage swapped
Phase and neutral of the mains supply reversed
The boilers that show this code
What our technician checks
- The supply wiring: live and neutral, to be swapped
- Floating or two-phase network: the dedicated parameter set to 0 (P43 on Calenta and Quinta Pro, 32 on Gas 210 Eco Pro, P34 on Gas 310/610 Eco Pro)