Remeha Fault code Remeha
A02.34

Automatic filling needed too often

Blocking: it retries by itself

The automatic filling device has to top up the system too often: the minimum time between two fills is not reached, and the next fill does not start. It is a warning: the boiler keeps running normally, but the cause must be found, for example a leak.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the main water tap is fully open.
  3. Look for a visible water leak on the boiler or the system.
  4. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show A02.34?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code A02.34

The meaning depends on the boiler: find yours below.

A02.34

For automatic filling, the minimum time interval between two requests has not been

Blocking: it retries by itself Calenta Ace-Matic, Tzerra Ace-Matic
A02.34

Auto-fill min int err

Blocking: it retries by itself Calenta Ace
A02.34

Minimum automatic filling interval not reached between two requests

Blocking: it retries by itself Tzerra Ace

What our technician checks

  • The boiler and the system, for leaks
  • The last fill: interrupted, or water supply pressure too low
  • The pressure switch wiring
  • The water filling tap
  • The circuit board, replaced if needed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.