Remeha Fault code Remeha
E00.06

Return temperature sensor not detected

Breakdown: the boiler is stopped

The boiler expects the signal of the sensor that measures the temperature of the water coming back from the system (the return) and does not detect it: the sensor is unplugged, badly connected or faulty. On the Calenta Ace, Tzerra Ace, Quinta Ace, Quinta 45-115, Calenta Ace-Matic and Tzerra Ace-Matic it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E00.06?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E00.06

The meaning depends on the boiler: find yours below.

E.00.06

Return T missing

Breakdown: the boiler is stopped Quinta 45-115
E00.06

Return temperature sensor not connected during boiler operation

Breakdown: the boiler is stopped Calenta Ace-Matic, Tzerra Ace-Matic
E00.06

Return T missing

Breakdown: the boiler is stopped Calenta Ace, Quinta Ace
E00.06

Return temperature sensor expected but not detected

Breakdown: the boiler is stopped Tzerra Ace

What our technician checks

  • The return sensor's wiring and connectors, up to the circuit board
  • The sensor's operation and its resistance
  • The sensor, replaced if faulty

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.