Temperature difference or no water flow
Breakdown: the boiler is stopped
This code does not mean the same on every boiler: on a Calenta, Tzerra M, Quinta Pro or Gas 210 Eco Pro (E:10), the difference between flow and return temperatures is too large (on the Gas 210 Eco Pro, between the heat exchanger and the return), because of a faulty or badly connected sensor or poor water circulation; on an Avanta, Avanta Plus, Avanta Platinum Plus or Aquanta (E10), no water is flowing through the boiler, because of too little water, air or a pump that has stopped. In both cases the boiler locks out and stays off until the cause is removed and it is reset (on a Tzerra M, which has no display, the light on the button then flashes red).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- On a Calenta, Tzerra M or Quinta Pro: check the water pressure. Above 0.8 bar, bleed the radiators; below it, top up with water to about 1.5 bar as the user manual explains.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E:10?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E:10
The meaning depends on the boiler: find yours below.
No water circulation during a ventilation cycle
No water in the boiler or pump stopped
No flow during the air purge cycle
Difference between flow and return temperatures too large
Difference too large between the heat exchanger and the return temperature
The boilers that show this code
What our technician checks
- The flow and return sensors: operation and fitting, replaced if needed (E:10)
- Circulation (direction, pump, valves), bleeding and water pressure (E:10)
- The heating pump and how clean the heat exchanger is (E:10)
- The water pressure and any leaks (E10)
- The circulating pump: shaft freed with a screwdriver, wiring, replaced if it still does not run (E10)
- Bleeding the air from the boiler and the system (E10)
- Whether the radiator valves are open (Avanta, Aquanta)